Cardinality: how many against how many

Every metric compares some real data with some synthetic data. Before asking which metric to use, ask how much data sits on each side. We write that as M:N:

  • M = the number of real (observed) years or replicates,

  • N = the number of synthetic realisations.

In the code (meteosynth.metrics) the real side is called the reference and the generated side the synthetic: evaluate(reference, synthetic). The reference is usually the training record, but nothing in the metrics assumes so.

Cardinality doesn’t decide whether you can compute a metric. You almost always can. It decides whether the answer means anything, and where the uncertainty is.


The four cases

Case

In words

Where the uncertainty is

What to do

1:1

one real year vs one synthetic year

on both sides, and you can’t remove it

Only compare structure (ACF, spectrum). Distribution distances are meaningless here, because two real years differ from each other too

1:N

one real year vs many synthetic years

on the real side: that one year’s weather

Well powered, but aimed at the wrong target. A difference could be model error, or just an unusual year

M:N

all real years vs many synthetic years

almost entirely on the real side

The normal case. Use the control band from Validating synthetic data

M:1

all real years vs one synthetic year

on the single synthetic draw

Change the question. Don’t ask “how far apart are they?”, ask “does this year fall inside the real ones?”, using a Rank (PIT) histogram

Two points that go against intuition:

  • 1:1 is best for time-structure metrics. Autocorrelation and the power spectrum describe one trajectory, so comparing one year with one year is fair. It’s the distribution metrics that fall apart at 1:1.

  • M:1 needs a different tool, not a looser threshold.

Which metric works in which case

Metric

1:1

1:N

M:N

M:1

Wasserstein, KS, quantile traces

⚠️

⚠️

✅

❌

Autocorrelation, power spectrum

✅

✅

✅

✅

Annual dispersion

❌

❌

✅

❌

Cross-correlation

⚠️

⚠️

✅

⚠️

Tail dependence

❌

❌

⚠️

❌

Rank histogram

❌

❌

⚠️

✅


A bigger N doesn’t fix everything

N is cheap in meteosynth. The model for each day is fitted once and shared by every realisation, so 1 000 realisations cost little more than 100. With N in the hundreds or thousands, the synthetic side of any metric is effectively exact.

That moves all the remaining uncertainty to the real side, and only more real years can reduce it. Three quantities each help with something different:

Increase…

Helps with

Does not help with

N (synthetic realisations)

precision on the synthetic side

anything on the real side

T (length of each series)

the longest lag or slowest cycle you can see

per-hour distributions

M (real years)

every control band, every tail estimate

anything about the generator

So if a reviewer asks “why 1 000 realisations?”, the answer is: so that the error bars belong to the weather record, not to the generator.


Folding: borrowing data to get enough of it

Twenty real years give only twenty values for “12:00 on 21 June”. That isn’t enough to draw a histogram. So you fold: you pool data along some axis until you have enough. Every fold buys sample size by making an assumption.

Fold

Real side

Synthetic side

The assumption you’re making

Across years ↔ realisations

pool the years

pool the realisations

the climate didn’t change over the record (it did, a little, for temperature). The safe default

Calendar window (±W days)

pool neighbouring days

already built in: the model was fitted to this pool

6 June and 6 July belong with 21 June. This makes the test about fidelity to the training data, not the exact date

Hour of day

pool all 24 hours

pool all 24 hours

the time of day doesn’t matter. This hides every diurnal error, so never report it alone

Along time

—

—

never. For ACF and spectrum, time is what you’re measuring

Rule of thumb: fold both sides the same way, and always say which fold you used. A number quoted without its fold can’t be interpreted.


Product scale: how long is each series?

Some metrics also need a long enough series (T). meteosynth can produce four “products”:

Product

What

T

Good for

D

one day

24 h

distributions per hour; ACF up to ~12 h

M

one month

744 h

adds multi-day persistence (2–10 day weather systems)

Y

one year

8 760 h

everything within a year; tail estimates become possible

KY

several years chained

K × 8 760 h

the annual cycle with more than one sample

meteosynth has no memory from one year to the next: each year is drawn fresh from the same climate. So nothing slower than one cycle per year can be found, whatever product you use.

For the questions an energy study asks, Y at M:N (all real years against many synthetic years) is the comparison to aim for.