Annual dispersion and the variance cascade

Suitability: ✅ Recommended — the headline test. meteosynth’s whole product is many plausible years. This test checks whether those years differ from each other the way real years do.

In plain words

Energy studies ask things like “what is the P90 yield?”, meaning the yield you beat in 9 years out of 10. That depends entirely on how much one year differs from another. If synthetic years are too alike, P90 looks too optimistic. If they differ too much, it looks too pessimistic.

The test has three parts:

  1. Annual means. Plot the distribution (ECDF) of the annual mean for the N synthetic years and mark the M real years as dots. P50 and P90 can be read straight off the plot.

  2. The variance cascade. Average the series over blocks of 1, 3, 7, 30, 90 and 365 days. For each block length, divide the synthetic variance by the real variance and plot the ratio against block length.

  3. The consistency band. With only M real years, the real spread is itself uncertain. A ratio inside the band is consistent with reality.

How it is computed

For block length \(L\) days, \(\bar X_L\) is the mean over a block and

\[r(L) = \frac{\operatorname{Var}_{\text{syn}}(\bar X_L)}{\operatorname{Var}_{\text{obs}}(\bar X_L)}\]

The band comes from the χ² distribution of a sample variance with \(M-1\) degrees of freedom. For the spread ratio (standard-deviation ratio) it is about 0.79–1.38 at M = 19, and about 0.74–1.59 at M = 11. That difference is a good reason to use the full record.

What it catches

  • Too little or too much year-to-year spread, and why. A ratio above 1 at short blocks that falls below 1 at long blocks means day-to-day variation is too strong while the year-scale component is missing.

What it misses

Comment for meteosynth

  • Expect the ratio to fall at long blocks. meteosynth has no year-to-year memory: a windy year in reality tends to be windy in every month, but synthetic years can’t do that. The test tells you how much this matters for annual figures.

  • Cross-check with the ACF. A generator with no memory between blocks predicts an annual variance of roughly \(\sigma^2_{\text{day}}\,\tau / 365\), where \(\tau\) is the decorrelation time from Autocorrelation (ACF). If the prediction matches, you have explained the result, not just measured it.

  • Irradiance and temperature: subtract the seasonal cycle (a day-of-year climatology) before blocking. Otherwise “January isn’t July” swamps the 30–90 day blocks. Temperature also has a warming trend across the record, which widens the real spread. Detrend, or report the trend alongside.

  • Needs the year product at M:N.

See also: Autocorrelation (ACF), Cardinality: how many against how many.