What each quantity physically is -- support, units, a human-readable name.
A :class:`VariableSpec` carries **constraints, not an identity**. It has no ``name``
field: several column names may legitimately share one spec, and a spec that owned a
name could not honestly serve four columns at once. The name lives on the registry key
instead.
All plane-of-array irradiance components share :data:`IRRADIANCE` -- same support, same
units, same night-time degeneracy. They differ in *which part of the incoming radiation
they count*, which is a fact about the data rather than about the constraints.
The names stay distinct even though the spec is shared, because
``poa_global`` is roughly ``poa_direct + poa_sky_diffuse + poa_ground_diffuse``.
Collapsing them into one generic ``irradiance`` column would let a global series train
under a name meaning direct: same units, same support, passing every validation, and
wrong by roughly a factor of two. Keeping the names distinct makes **the column name the
provenance**, which is why nothing in this package needs a metadata sidecar.
The same argument runs across *planes*, which is why :data:`IRRADIANCE_HORIZONTAL` is a
separate object despite carrying identical constraints. ``ghi`` and ``poa_global`` are
the same physical quantity measured on different surfaces, and they differ by however
much the array is tilted -- so a horizontal series trained under a plane-of-array name is
the factor-of-two error again, in a second dimension. The constraints coincide; the
:attr:`~VariableSpec.long_name` does not, and that string is what
:func:`meteosynth.adapters.validate_support` quotes back to a user who is, by
construction, in the middle of debugging where their numbers came from.
The registry is what makes the package variable-agnostic: a column is modellable **if and
only if it has a spec**. Register one and it works, with no change to the package::
>>> register("rel_humidity", VariableSpec((0.0, 100.0), "%", "Relative humidity"))
>>> get_spec("rel_humidity").support
(0.0, 100.0)
Pure data, no pandas -- mirrors the free-function style of :mod:`meteosynth.day_window`.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Iterable, Optional, Sequence, Tuple
__all__ = [
"VariableSpec",
"IRRADIANCE",
"IRRADIANCE_HORIZONTAL",
"IRRADIANCE_COLUMNS",
"TEMP_AIR",
"WIND_SPEED",
"get_spec",
"register",
"unregister",
"registered",
"irradiance_columns",
"resolve_irradiance",
]
[docs]
@dataclass(frozen=True)
class VariableSpec:
"""
The physical constraints of a quantity, independent of what a column calls it.
Parameters
----------
support : tuple of (float or None, float or None)
``(lower, upper)`` physical bounds. ``None`` means unbounded on that side.
Sampling is truncated to this range, so an out-of-support value becomes
unsamplable by construction rather than merely unlikely.
units : str
The units the data is expected to already be in. Declarative for now:
ingestion validates against :attr:`support`, it does not convert.
long_name : str
Human-readable description, for plots and error messages.
Notes
-----
Specs are **declared, not inferred**. Inference reads the sample rather than the
physics and gets both hard cases wrong: ``wind_speed``'s observed minimum is 0.07 in
the shipped record, so inference would call it unbounded below; a July-only
``temp_air`` subset is entirely positive, so inference would call it non-negative.
Both wrong, and silently so.
"""
support: Tuple[Optional[float], Optional[float]] = (None, None)
units: str = ""
long_name: str = ""
[docs]
def clamp_domain(self, data_min: float, data_max: float) -> Tuple[float, float]:
"""
Intersect an observed data range with this spec's physical support.
This is the whole of support enforcement: restrict the evaluation domain
*before* building a CDF, and ``np.interp`` cannot then return a value outside
it. Truncation is applied to the observed range rather than replacing it -- the
data still governs where the mass is, the support only says where it may not go.
Parameters
----------
data_min, data_max : float
The observed range of the values being fitted.
Returns
-------
tuple of (float, float)
The clamped ``(min, max)`` domain.
Examples
--------
>>> IRRADIANCE.clamp_domain(-8.1, 81.0) # negative tail cut at the bound
(0.0, 81.0)
>>> TEMP_AIR.clamp_domain(5.9, 20.1) # nothing to clamp
(5.9, 20.1)
"""
lower, upper = self.support
if lower is not None:
data_min = max(data_min, lower)
if upper is not None:
data_max = min(data_max, upper)
return data_min, data_max
#: Plane-of-array irradiance. Shared by every component -- see the module docstring for
#: why the component names stay distinct despite sharing one spec.
IRRADIANCE = VariableSpec((0.0, None), "W/m2", "Plane-of-array irradiance")
#: Horizontal-plane irradiance -- ``ghi``, ``dni``, ``dhi``, as PVGIS TMY and most
#: reanalysis products supply it. Physically identical constraints to :data:`IRRADIANCE`,
#: deliberately a distinct object: the ``long_name`` reaches the user in
#: :func:`meteosynth.adapters.validate_support`'s error text, and naming a horizontal
#: quantity "plane-of-array" would misinform at precisely the wrong moment.
IRRADIANCE_HORIZONTAL = VariableSpec((0.0, None), "W/m2", "Horizontal-plane irradiance")
#: Air temperature. Bounded below by absolute zero; unbounded in practice.
TEMP_AIR = VariableSpec((-273.15, None), "degC", "Air temperature")
#: Wind speed. Non-negative, but unlike irradiance it never touches the bound.
WIND_SPEED = VariableSpec((0.0, None), "m/s", "Wind speed")
#: Irradiance **totals**, most preferred first -- the answer to "which column here is the
#: irradiance?" when a caller has not named one.
#:
#: Only totals appear. A component is a *part* of a total, never "the irradiance":
#: ``poa_direct`` is roughly 70 % of ``poa_global``, so returning it for a caller who asked
#: for the irradiance would be the factor-of-two error the naming scheme exists to prevent,
#: arrived at from a new direction. :func:`resolve_irradiance` therefore raises rather than
#: guessing when only components are present.
#:
#: ``poa_global`` outranks ``ghi`` because plane-of-array is what this package models --
#: but a record holding only ``ghi`` resolves to ``ghi`` rather than erroring, and the
#: *returned name* is what every caller then uses, so the plane is never silently lost.
IRRADIANCE_COLUMNS: Tuple[str, ...] = ("poa_global", "ghi")
#: The specs that make a column an irradiance. Membership is by **identity**, which is what
#: :data:`IRRADIANCE_HORIZONTAL` being "deliberately a distinct object" is for: register a
#: column against one of these and :func:`resolve_irradiance` discovers it, with no change
#: to this package and no second list to keep in step.
_IRRADIANCE_SPECS = (IRRADIANCE, IRRADIANCE_HORIZONTAL)
#: Column name -> spec. Several names may map to the same spec object.
_REGISTRY: dict[str, VariableSpec] = {
"poa_global": IRRADIANCE,
"poa_direct": IRRADIANCE,
"poa_sky_diffuse": IRRADIANCE,
"poa_ground_diffuse": IRRADIANCE,
"ghi": IRRADIANCE_HORIZONTAL,
"dni": IRRADIANCE_HORIZONTAL,
"dhi": IRRADIANCE_HORIZONTAL,
"temp_air": TEMP_AIR,
"wind_speed": WIND_SPEED,
}
[docs]
def get_spec(name: str) -> VariableSpec:
"""
Look up the spec registered for a column name.
Parameters
----------
name : str
Column name, e.g. ``"poa_direct"``.
Returns
-------
VariableSpec
Raises
------
KeyError
If nothing is registered under ``name``, with the registered set and a pointer
to :func:`register` in the message -- an unregistered column is a normal thing
for a user to hit, so the error has to say what to do about it.
"""
try:
return _REGISTRY[name]
except KeyError:
raise KeyError(
f"no VariableSpec registered for {name!r}. Registered: "
f"{registered()}. Use register({name!r}, VariableSpec(...)) to add it."
) from None
[docs]
def register(name: str, spec: VariableSpec, overwrite: bool = False) -> None:
"""
Register a spec under a column name, making that column modellable.
Parameters
----------
name : str
Column name to register.
spec : VariableSpec
Its physical constraints. May be an object already registered under another
name -- sharing is the intended usage for related quantities.
overwrite : bool, optional
Permit replacing an existing registration. Defaults to ``False`` so that a
typo'd re-registration is an error rather than a silent redefinition of what a
column physically is.
Raises
------
ValueError
If ``name`` is already registered and ``overwrite`` is False.
"""
if name in _REGISTRY and not overwrite:
raise ValueError(
f"{name!r} is already registered as {_REGISTRY[name]!r}. "
f"Pass overwrite=True to replace it."
)
_REGISTRY[name] = spec
[docs]
def unregister(name: str) -> None:
"""
Remove a registration.
Mainly for tests, which must be able to restore the registry to its shipped state;
a leaked registration would otherwise make one test's columns modellable in another.
Raises
------
KeyError
If ``name`` is not registered.
"""
del _REGISTRY[name]
[docs]
def registered() -> tuple[str, ...]:
"""
Every registered column name, sorted.
This is the authoritative answer to "what can be modelled?" -- generators validate
``attr_str`` against it, and ingestion keeps exactly these columns.
"""
return tuple(sorted(_REGISTRY))
[docs]
def irradiance_columns() -> Tuple[str, ...]:
"""
Every registered column name whose spec is an irradiance spec, sorted.
Derived from the registry rather than hand-listed, so a user who registers
``poa_reflected`` against :data:`IRRADIANCE` -- the sharing that
:func:`register` already documents as intended -- becomes resolvable with no change
here.
"""
return tuple(
sorted(name for name, spec in _REGISTRY.items() if spec in _IRRADIANCE_SPECS)
)
[docs]
def resolve_irradiance(
columns: Iterable[str],
prefer: Sequence[str] = IRRADIANCE_COLUMNS,
) -> str:
"""
Pick the one irradiance column to model, by what is available.
This is what lets a caller stop caring whether their record came from PVGIS hourly
(``poa_global``) or a TMY (``ghi``). It **never renames or converts anything**: it
returns a name that the caller then uses everywhere -- ``attr_str``, plot labels,
saved output -- so the quantity and its plane travel with the result.
Parameters
----------
columns : iterable of str
Column names to choose from, e.g. ``dataset.frame.columns``.
prefer : sequence of str, optional
Preference order over *totals*. Defaults to :data:`IRRADIANCE_COLUMNS`.
Returns
-------
str
The chosen column name.
Raises
------
LookupError
If no irradiance column is present, or if the only ones present are components
of a total that is itself absent. Both messages name what was found and what
was looked for, because a user hitting this is by construction trying to work
out what their data holds.
Examples
--------
>>> resolve_irradiance(["poa_global", "temp_air", "wind_speed"])
'poa_global'
>>> resolve_irradiance(["ghi", "dni", "dhi"])
'ghi'
>>> resolve_irradiance(["poa_direct", "temp_air"]) # sole candidate, no ambiguity
'poa_direct'
"""
present = [col for col in columns if col in irradiance_columns()]
for name in prefer:
if name in present:
return name
if not present:
raise LookupError(
f"no irradiance column found. Looked for {irradiance_columns()}; "
f"register one against IRRADIANCE or IRRADIANCE_HORIZONTAL to add it."
)
if len(present) == 1:
return present[0]
raise LookupError(
f"cannot choose an irradiance column: {sorted(present)} are all components, and "
f"none of the totals {tuple(prefer)} is present. A component is a part of a "
f"total, not the total -- name one explicitly, or build the total first."
)