# Midnight seam **Suitability: ✅ Recommended** for wind and temperature. **Skip for irradiance.** ## In plain words meteosynth builds each day separately and then **stitches** the days together at midnight with a separate model. This test looks at the stitch: is the jump from 23:00 one day to 00:00 the next as large as in real data, no larger and no smaller? ## How it is computed For every pair of consecutive days: $$\Delta = X_{0,\text{today}} - X_{23,\text{yesterday}}$$ Compare the distribution of Δ between real and synthetic data, for example with {doc}`wasserstein` or by overlaying the two histograms. ## What it catches - A bad join between days: steps that are too big, or phase jumps. In an energy model these look like false battery charge/discharge cycles. - It is the **only** metric that tests the cross-midnight model on its own. ## What it misses - Everything inside the day. ## Comment for meteosynth - **Irradiance:** 23:00 and 00:00 are both dark all year, so Δ = 0 on both sides and the test passes trivially. If the join matters for irradiance, check **the sunrise ramp** instead: does it start at the right hour and rise at the right speed? - **Temperature:** the most informative variable here. Overnight temperature changes slowly, so a bad join would show as a clear step. - Needs series of at least two days (product M or Y). **See also:** {doc}`autocorrelation`.